why normally Generator rating are between 11Kv to 22Kv?

Answer Posted / nithi

The power generation found more economical,when it is
generated in the voltage level upto 15kv.that's why the
generator in the power sector are rated upto 15kv.

Is This Answer Correct ?    11 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how i chosse capacitor bank if my energy meter is 48 kvr? tell me capacitor bank chossen formula?

1920


please send me privious exam's queation papers of section engineer(electrical).

1604


if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1409


if i am in front of transmission line how to know that current direction without any equipment

1258


What are the basic elements used for modeling mechanical translational system?

615






sir iam from electrical and electronics branch ,can i appear for the hpcl offline requirtment? if yes please mail me on vikram_raju25@yahoo.co.in

1554


What is thresh hold value of current?

1603


How capacitor improves pf

1203


how can we calculate the ratio of caustic soda and water in lrs.

5184


how to find impedance , mutual indatnce in transmission lines

1670


2. Modify your design in question 1.a so that the circuit works according to the following function table X Y F 0 0 Clear 0 1 No Change 1 0 Parallel Loading 1 1 Count 3. Design a circuit that detects the pattern 010 in a serial input X considering: 3.a Overlapping 3.b No overlapping

1457


why do we lay up the core of a cable?

1611


what is the function of capacitor duty contactor in an capacitor panel???

3626


how to calculate power consumption in slip ring motor at different step

1712


Help need in transformer !? Hello Friends The parameters of 2300/230 v 50hz t/f is R1=0.286 ohm R`2=0.319 ohm Rc=240 ohm X1=0.73 ohm X`2=0.73 ohm Xm=49.2 ohm Secondary Load impedance ZL=0.387+J0.29 solve the exact equivalent circuit with normal voltage across primery.. I know every thing but i cant find CURRENT I1=? and I`2=? Please help me give solution or only Formula please please...

2526