why transformer ratinh is in KVA????/
Answer Posted / peter
coz KW or HP makes no sense.....transformer is not a power
conerter involving mechanical energy.....i mean...it just
transfers electrical energy ....
Is This Answer Correct ? | 1 Yes | 4 No |
Post New Answer View All Answers
Do inductive loads have distorted current waveforms ?
1. for eg, capacitor is used for many purposes(it act as filter, oscillator, bypass capacitor, memory storage etc...) 2. Please tell me some example circuits for different uses of capacitor( whenever and whereever and however we used capacitor as a filter, oscillator tuning etc..) 3. similarly for inductor and resistors(it act as what?) and when and how we want to act as like that?, and how we can used these components depends upon our requirments with example circuits and explanation? design to act as these components depends
1.what is difference between ATS & STS main use. 2.what is difference between ACB& VCB With symobles,and main partes, manimum range. 3.How many types of relays and main function.
hi friends ,iam working as genset AVR service engineer in electrical field from past 2 yrs throughout india . i plan to shift in some other job without travelling in same field because i con't travel,i dont know what i do for that so please guide me what job is suited for me,how i can serch the job please anybody helpme iam totally confused
what is control supply rating of a machine
How can we calculate the motor frame sizes?
in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com
I need a formula to calculate the size of cable as per load but in the terms of length. Please Reply me as i search lot of sites but i did not get the answer.
Is there any problem about which the drive (inverter) doesn't show/display the alarm and/or fault but instead of this , it doesn't work ? I want to know that could there be any kind of problem in the drive when the drive doesn't display the alarm and/or fault ?
What do you mean by turns ratio of instrument transformer?
i want to know how to determine that a surge arrester work properly in 11kv system. and how to test a 12kv surge arrester
What is meant by time harmonics and space harmonics?
HOE WE CAN IMPROOVE BY USE OF CAPACITOR
What is the Minimum winding resistance of motors ( small & big)? referance range
what questions will be asked for 11/33KV licence interview APSEB hyderabad. Can any one share question and answers.