why generaotr rating is in kva and dc motor in kw?
Answer Posted / hemraj
generally,the rating of any machine is decide by losses of
that machine depends on what factor.losses in gen. are
depend only on generated voltage & gen. current. so rating
of gen. is in kva.
in dc motor losses are depend on voltage & current and this
losses are also depend on application of dc motor i.e power
factor of load which is connected to that dc motor. so
rating of dc motor is in kw.
| Is This Answer Correct ? | 18 Yes | 9 No |
Post New Answer View All Answers
wheather the size of windings in motor and generator are the same
How to calculate energy stored in a capacitance
Brief me about maintenance planning & sheduling of machine tool.
Why have to use copper cable for local isolator to motor ?
how can we calculate the ampacity of the electrical wire/cable. and what are the factors must be considered. pls. elaborate.
Whether should be the oil level in OCTC transfomer? It should be upto winding immersed completely or should be upto tap changer s/w? How it will affect the performance of the transformer. Rating may be 33KVA
In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.
Give atleast 20 alternating current apparatus and devices.
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
Plz tell me how we can find that particular company has vacancy or not
in ring main system we use the isolater b/w transfer bus and main bus if we r not use isolatar than wat will be the effect in our sys.
State kirchoff current law?
hi, i have 3x200KVA and 2 x 80KVA UPS with battery bank of 150AH 68Nos. and 100AH 204Nos., i need to install AC either ductable or PAC type, so can you help me to calculate heat load and capacity of the AC to install.
why occ characteristics curve in not tracing back when we are bringing back the rhoestat?
In case of generator when we consume more power produces by it why load on generator increase and starts sound more. and how it is adjusted..