how much capacity(rating) of generator required to operate a
load of 100kv.

Answer Posted / shashidara reddy

rating purely depends on load not on vltg.

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what will happen when the dc supply is given to the capacitor?

1006


Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?

1521


when ID fan will immediately stop through VFD what exactly cause and problem the ID fan

986


how is control wiring coding is done in a CRP panel ?

1536


Zone of protection and tripping scheme of arc protection relay.

1402






working function importance of mdc meter

1695


Is a 300w induction motor used in a food processor as powerful as a 1000w DC motor.

1737


What is meant by Load Encroachment in OHL Feeder Protection?

3107


what is KSR type transmission tower? What is LSR type transmission tower?

4628


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1561


If we need 4c× 50mm sq cable but it's not available so we can pull 4c×25mm sq two cables?

924


1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?

1762


being an electrical engineer why you wanna come into software i have an very good academics what answer i have to give

1477


What are the Full Forms of TVM, MTL, CVT ?

914


We have given to 3phase supply to ups system & how can coming netural

1646