i have 2 motor of same rating. on no load condition one
motor take 1.6A but other motor is taking 4.8A. what is the
reason of this. please explain with proof.

Answer Posted / ashok sharma

OK. It is right that in star motor taking 1.6A & in delta
motor is taking 4.8A. but Please prove this with example.
Suppose both motors are new .

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is miller crystal oscillator? Explain its operation?

683


why capacitance effect is predominant in underground cable transmission and inductance effect is predominant in over head line transmission?

3192


in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply

1573


what is submersible pump?what is different between motor and sub motor?

1603


how to generator maintenance (A Check, B check,Etc)

1779






how slip power recovery system work

2536


Calculate torque developed by the 3-phase, 5 H.P., 4 pole induction motor runs at 1500 rpm A 23 N-m B 21 N-m C 10 N-m D 0 N-m

4361


a governer in an Ic engine controls the

705


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1500


can we synchronize star system generators with delta system transmission line ? and how ?

2313


1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?

1768


What are the site acceptance tests for power cables, DG Sets, LT panels & 30kVA UPS ?

1900


Is it required to do earthing in 2nd shop if earthed armoured cable is laid from 1st shop ?

1437


Classify driling machines.

704


What is MSL designation of a motor and same may be provided in details.

1229