What happens to an electric motor if it has poor or no
ventilation. Will it burn out? If it will, how long it
will run before it burn out?
Answer Posted / john h
This actually is hard to answer because the heat generated
may not actually be surpassing the thermal capacity of the
motor to disapate heat even unvented. If the motor is
producing excess heat which surpasses the operating
specifications of the motor design then it will reduce its
lifespan and fail. It also could be producing excess or
reduced windage (air resistance) reducing the effectiveness
of the motor.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what happen if generator of micro hydro running at only a small percentage of its capacity, as a comparison, if the diesel generator that runs on only a fraction of its capacity there will be a wet stacking
I would like to know that the fault curretn at base load and at 10% generation will be same? Fault level of BUS remain same with different generation?
What is domestic transformer? Draw the connection of domestic transformer.
how can i get the formula to find out the cable size if i know the load of main fuse protection.
What is real time power factor control panel(RTPFC)?
What is state space method ? Why its used ? Can it applicable on linear, non-linear, 1st order, higher order, homogeneous, non-homogeneous, open-loop , closed loops , stable & unstable systems ?
How to protect sensitive loads such as Dosing pumps inside a factory from voltage surge/voltage fluctuation.
Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.
draw the restricted earth fault protection circuit install on power transformer and identify its parameters and draw C/C curve of it
Which contains in POLE ASSEMBLY of a 11KV Kirloskar-make SF6 (Model No-FP620A12)? Will u clarify with drawing?
is it value of power factor is more than unit. whats effects in the source supply
What are the basic elements used for modeling mechanical rotational system?
WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.
In CTs tan delta point should be earthed , what is the reason behind it?
Whats the minimum value for I.R. that can be allowed for HT & LT alternators for operation?