Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

when a primary current injection test is required, it is
accomplished by what?

Answer Posted / brijesh

Primary current injection test require at the time of
commissioning to the current transformer.

The purpose of it is to check the ratio of C.T.

and for checking of C.T. circuit.

The test is conduct by means of primary injection test set.
In test set there is a current transformer and variac.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Whether should be the oil level in OCTC transfomer? It should be upto winding immersed completely or should be upto tap changer s/w? How it will affect the performance of the transformer. Rating may be 33KVA

1841


what types of electrical & mechanical test conducted in switchyard?

2244


the site measured knee point voltage of protection class CTs should be greater than rated knee point voltage? what about meetering class CTs. Should it be below the rated knee point voltage?

2293


What is the actual meaning of thermal power efficiency ?

2178


Why you are switching off arc protection mcb when you are taking shutdown for lv board.

1704


A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.

2600


What effect does a very low impedance have on the Voltage regulation? On the short-circuit current?

6307


from which subjects most of the technical que will b asked for hpcl(electrical).pls help me

2008


In a carnot engine with an efficiency of 40%, the heat rejected to the sink at 27 C is 60 kJ, then the heat supplied in kJ to the engine by the sources is

1082


If we have use two power cable for incomer, that time how many use cbct for earth leakage protection? 1 or 2 if 1 way? If 2 way?

2106


why does a dc machine has high efficiency while working as a generator than as a motor ..

2011


Is neutral transformer can be called as control transformer?

1984


what is the advantages og idmt relay over magnetic relay??

4250


why a tester wont shock while testing the power in house

1863


What happens if we run alternator on under frequency? 

2122