Answer Posted / sandeep negi
widal by tube consider to be more accurate than by slide
method
it is considered 2 b more helpful in the diagnosis
as its gives us rough idea about abs present os not and in
how much concentration
widal by tube
> 4 rows r arranged of 8 clean tubes
> 1 2 3 4 5 6 7 8
> 8th row is our negative control
now
1 clean tube for master dilution is taken
this is our master dilution (1:10 )
now transfer this master .5ml to 1st nd 2nd rows
add saline .5ml fron 2nd row to 8th row
u have to tak .5ml saline in 1st row only
here dil will be 1:20 after adding antigen .5ml
from 2nd row .5ml from master +.5 saline form = 1ml which
will be diluted serially
to other tubes horizontally
which will double our dilution afetyr addition of
respectine antigen(0,h,ah nd bh)
(4.5ml salin+.5ml sample)
| Is This Answer Correct ? | 54 Yes | 22 No |
Post New Answer View All Answers
How to sterlize yeast on mold plates?
Why are Plasmodiophoromycetes not true fungi?
Describe about the Antibiotic resistance in plant groth promoting bacteria?
Maximizing Lambda Phage Growth really Inhibits Lysogeny?
Explain the Virus plaque assay for VSV ?
How are stains classified?
Describe the Storing of bacterial colonies ?
Explain about the buoyancy of yeast in media ?
Why did you decide to study microbiology? What do you like about it?
What is the reaction characterized by degranulation of mast cells as a result of antigen-antibody complexes affixed to cell surfaces?
Explain the degradation of acrylamide?
Why we maintain 121degree centigrade for autoclave? why we are not maintaining the temperature above or below 121degree? what is the reason?
What are the uses of inspissator?
Explain the mechanism of antibacterial action?
Give an account of Viral isolation?