How check electrical motor winding.

Answer Posted / anil bhatia

1. Check the resistance of all windings. In case of three
phase motors resistance of all windings should be same.

2. Check the insulation resistance with megger. It should be
near about 1M-Ohm.

i am agrred by the statment given by friend but also in
some cases both above1 and 2 we find ok and problom we
find in iduction reactance which only can be measured by
motor checker .

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why Induction Generators are not "Black start" ? and apart from WTGs where this types of generator are generally used?

2221


Why are the laminations insulated from each other?

650


what is mean by PIR in circuitbreaker and give me detail of that?

3097


The screw thread commonly used for transmission of motion is one of the following types of threads

695


How to Decide the Location of Earth pit for Compressor in Oil Depo? and How to measure the resistance of earth pit Pls explain me with the help of Circuit Diagram?

1919






for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1521


i am completed in B.E(Electrical and Electronics Engineering) with 8 months experience in Quality Control Engineer at Bharathi Industries,Coimbatore.

1474


How to calculat the ratio of HT\LT in energy meter

2129


salam,hi, i need to know what the spesification of 300amp msb...

1597


why +24 v and -48 v give to BTS? If -48v protect from surge then why we not use -24 v?

1422


What is warm / cold start of HT motors. How many warm start & cold start are possible in a day?

1572


what is doubling factor in making current of a breaker?

1567


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2264


1.why are not using acb 33kv ht side? is there any problem 2.what is difference between acb,vcb,sf6 breackers? 3.what is the function of invertor and convertor in ups?

1687


I am a electrical engg. diploma holder,applied for junior engineer (electrical),Kolkata RRB. Have I to attend all electrical,mechanical&civil portion in written exam.???

15193