Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

4-Why we measure the insulation resistance of main core and
frame in spite of that must be connected with ground

before energize the transformer?

Answer Posted / mrudang

the 2 nd answer is quite right ,

actually we have to know the value of core insulation
its resistance , for its condition ,we have the standads
for it , and match with those value

if there is leakge current , the value should be lesser
we are doing between phase- earth , and phase to phase
so we match the phase to phase value also

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Will any motor burn if voltage provided is lesser than the rated voltage???? If yes, then how is speed control possible with voltage control

2165


How to Calculate Current Rating of SDFU (Switch Disconnector Fuse unit) for Protectionof Capacitor Bank connected to Busbar of 800Amp,in LV side of 11/0.433KV, 250KVA Transformer?

5402


Explain bypass capacitor?

1173


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2723


The simple way of finding the leakage quantity and % in compressed air distribution system

1681


how to find out cable size if load is 2800 watts, 230 volts AC supply and load distance is 1800 meters

1611


what is relation between ct and pt ratio with multiplication factor of a energy meter? is there any other factor on which multification factor depend?

2349


area control error

1745


what is the difference between changer, converter and transformer?

1550


A 500 V shunt motor runs at its normal speed of 250rpm when the armature current is 200A. The resistance of the armature is 0.12 Ω. Calculate the speed when a resistance is inserted in the field reducing the shunt field to 80% of normal value and the armature current is 100A.

2521


how to select electronic timer(Star-Delta) setting for diff. rating motors

1961


How will A Medium voltage circuit breaker(11 kV voltage level) operate under short circuit fault condition whether It is having short circuit release like Low voltage circuit breaker or relay should be given?

1949


what will be happen if earth point is being used for as a neutral point for raw power , and same will be used for ups earthing

2082


Which is the largest hydropower station in the world?

1151


TCS IS IT COMPANY THEN WHY DO THEY NEED ELECTRICAL &ELECTRONICS ENGINEERS?

1949