if voltage is not builed up in small generator what will be
the reason?

Answer Posted / swayanjit

if voltage build up is not possible then there may be open
circuit in the field or armature, may be due to dirty
commutator, may be the speed less than the critical spped,
may be the field resistance greater than the critical
resistance.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is line resistance of cable & how it can be measured ?

968


A 3-phase IM is supplied from 50 Hz system. It runs at speed of 1440 rpm and slip equal to 4 %. Calculate number of pole pairs. A 1 B 6 C 2 D 3

1585


A low wet bulb temperature indicates

699


What is an alternator impedance value?

2409


state working of halogen lamp?

1366






if there is nutral in phase why we use earthing wire and grounding? even at fault condition the fault current flows to neutral (it is a lower path)

1342


how can i get an electrical c-certificate?

1799


dear all i am kumara now current working in electrical designing of control and relay panel i want learn some substaion design then any book are available. pls mention name and authour

1516


EXPLAIN METOD OF IMAGE OF TRANSMISSION LINE/ WHAT ARE ITS PRACTICAL APPLICATION?

1425


in star-delta tranformer,if the input of star connection is 400/7v 3 kva then what is the output of delta connection?

1720


how will reduce the voltage. if 12volt/250ma transformer toreduce 6 volt

1530


What is the meaning of Insulation H for transformers????

1620


can i connect REF and Differencial relay in 1 CT core for transformer protection?

1467


Is it good to short Neutral and Ground in the PLC or DCS main Power supply. Pls give YES or NO with reasons...? Simarpreet

2055


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1661