I have connected 04nos. earthings to a transformer through
04nos. earthing pits seperately. 02nos. earthings are
connected to T/F body, and 02nos. earthings are connected to
T/F neutral.T/F capacity is 2000KVA, 11KV/415V. But after
completing of 02 years successful operation ,we are
facing following problems-

1. CT/PT occured blast one time
2. HT cable box occured blast two times
3. One body earthing strip and one neutral earthing strip of
transformer are overlapping at some places. Whenever these
two strips are pressed at overlapped points, they made spark.

What is the reason of spark?

Please explain the reason & rectification of above problems

Answer Posted / santosh kawade

Please contact me Santosh 9224 69 3116,

Probably site inspection require to sortout your problem.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if voltage bt phase & nutral is 38v in a panel board . whats the root cause.

1822


please tell me, how i clear the objective test? when i studied form the one book after i solved the objective ,that time i solved that qes. but if i tried solve objective form the other book then i could not solved these que.

1241


how we can do the insulation on secondary of ct explain and so that tan delta will within limit

1452


what is th basic difference between a d latch time line and a d flip flop time line???

1469


How do you calculate the actual power consumption of an inductive load appliance. Say, a deep freezer of 200watts

1656






What is CCM in Electrical ? where can we use this material?

942


What is the difference between isolators and electrical circuit breakers?

629


1. A bomber drops a bomb from an aircraft flying at 2000 km/hr. at an altitude of 7km. The speed at which the bomb will strike the earth would be

1482


What is kvar?

857


What is the type of feedback used in an op- amp schmitt trigger?

644


Why the cores of large transformers build up of circular cross section?

1745


i am an maintenance engineer. one distribution board have 5 feeder. recently its ELR trips frequently, but it take some times after trip( 10min,20min..)but 3 feeder no load. two feeder only loaded. i checked one feeder IR value all values are above 50Mohm.but B phase to Earth is only 9Mohm.any problem about low value

1416


What is the general system requirement of alternator?

1326


why we use 630mm single core cable for transformer secondary side and why two neutral cable

1409


What is meant by reverse polarity and how it can be fixed?

747