OUR METER READER TAKE READING OF INDUSTRIAL CONSUMER.THEY
ALWAYS ASK HOW TO INCREASE POWER FACTOR FROM 60% TO 99 % TO
AVOID PENALTY OF POWER FACTOR.
Answer Posted / pillay
The power factor is low for industrial customer because the load is usually inductive due to the many motors installed.
Power supply companies sell by calculating KWH used.Thier generators maximum capacity is limited by the amps the generator can produce at a fixed voltage.
So calculations will tell u that lower power factor means higher amps for the same KWH &AND HIGHER PF MEANS LOWER AMPS for the same kwh. thus the power supply companies can make more money from the same generator and also save on other expenses.
power factor is improved by connecting reactive load in parallel.this reactive power is loss free and you dont pay for the power consumption.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
how to calculate the power factor when instantaneous voltage and current has harmonics in it ?
What is nyquist contour?
When a square wave is applied to primary of a transformer then what will be output wave form of secondary ?
How to measure current and voltage in an ELV circuit
What will happen if the voltage in my house drops from 220V to any lower voltage?
What is the difference between circuit breaker and isolator
Dear all i want to know SEWA Electrical Supervisor Licence test Previous Year Questions ? If any body know please send to me zohairaukllah@yahoo.com
what is solkor relay and which condition it will act?
define superposition theorem thevnin theorem ,norton theorom?
how is the cable tray designed & how its total length is calculated for an Industrial plant Say for Ex. (500KW Motor Load)
What is the difference between relays and contactor construction wise?
How can we increase the capacity of Energy.?
I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?
Explain in brief description about the operation of DG sets.
What are the components connected in between the power supply coming from an electric pole to HT & LT Panels in a large commercial building or how the power supply connected from Electric pole to Transformer & then to the HT & LT panels of a building? Please send me answers via mail, my id is yogiagarwal@gmail.com. If possible, please give a line diagram.