the distance from my office to d.g is aprox 400mtrs and
voltage drops ibn my office near about 40 volt what should
i do p[ls suggest.

Answer Posted / sabale.dnyanehswar@gmail.com

IF U ASKING ABT DC Voltage then ans is
1. u have to increase the sq.mm size of the cable. i.e if
u r laid cable size is 16 sq.mm. u can go to 25 sq.mm.
2. u have to increase u r battery Amphour rating . by
replacing it with higher rating.

if u asking abt AC voltage:
1. check the DG set terminal voltage if voltage is not
proper then check at AVR terminal. if there also not ok.
then check it with another AVR card.
2. if AVR is OK then check any leakage of cable with taking
megger & continuty with earth.
3. if problem is found in cable then replace with new one
or increase the rating of cable.
if everythink is ok. then take voltage at receiver end with
out load. one by one increase the load at every time
voltage reading. if found prob. in another ckt. rectify it.
The range should be +- 5% should be accepted.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why and how voltage sharing in transformer, during magnetic balance test ?

1798


Dear friends I want to design busbar for1600 kva transformer(i.e2100 amps) what are all the factors to be considered before selectinga busbar what are all the standard sizes of busbars what is the formula for finding current of copper and aluminium busbar

1476


What is inrush current? how can calculateit? what is the affect of it?

1533


What is instrumental error?

683


please send me previous year questions of jspl through which i could prepare myself for the test.

1368






How do we calculate transformer oil in liter from the rating of the transformer.

1170


what is the formula for hv test for cable and circuit breaker..????

1530


can indirect loading be called as phantom loading?

1553


what is the working principle of a DG Set, Alternator, & exiter

9738


iam working in power plant. In hot places tube lights are glowing at the end portion only. what is the reason for that?

1453


How to check the Bushings of the transformer?

1261


In 11/0.414 KV Parralel supply network with Bus tie closed what will be the fault level is it doubled or halved??

1631


high voltage transformer input voltage,current and amps rating..distributed transformer input voltage,current and amps rating...

1535


The efficiency of a 100kva transformer is 0.98 at full load as well as half load , for this transformer what is the Copper loss at full load ?

1797


how u select control transformer for a mccb panels or any panels?for expample we hav 440 volts maim supply and control volts is 230v?

1668