What is the Difference Between MCCB & ACB & VCB
Answer Posted / kantharaju k c
MCCB-- Moulded Case Circket Breaker
ACB -- Air Circket Breaker
VCB -- Vacume Circket Breaker
MCB we use from 0 to 64 Amp.
MCCB we use from 64 to 800 Amp
ACB we use above 800 Amp
More ever at much higher current level we use VCB because
at higher current the air around it get ionised and become
conducter which causes short ckt. so at much higher current
level we generaly use VCB.
Is This Answer
Is This Answer Correct ? | 44 Yes | 20 No |
Post New Answer View All Answers
what is the difference between earthing and unearth
As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?
how give earthing conection to household equipment?
In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?
In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.
How short circuit MVA(Fault MVA) in a power system calculated for calculating number of earth plates ?
how flow current in 220 kv line to line
Why single phase induction motors are not self starting ?
which motor have relatively high power factor and what is reason for have high pf? 1.capacitor run motor 2.shaded pole motor 3.capacitor start motor 4.split phase motor
What is method of calculating the fault current for a MDB, 50KW, 3PH, 415V, 50HZ?
r we are using in gas turbine mark (5) frame (6) (made in india Bhel 1997) Ā
plz tell me,ht and lt panel terminals in substations explain beiefly
What are the different types of controllers?
How can we increase fuel-power ratio of any DG set?
How to test REF relay testing for LV panel as per Kahramaa standard?