transformer test

Answer Posted / dany

Basically transformer tests are of two types.
1)short ckttest 2)open ckt test
short ckt test gives us 1)copper losses 2)voltage regulation
3)lekage impedances(ie. resistance and lekage reactance )
open ckt test gives us 1)core losses 2)parallel component
values (ie Rc and Xm)3)secondary voltsge

Open ckt test will be done on lv side ,while short ckt test
will be on high voltage side

Is This Answer Correct ?    6 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to calculate pitch, gauge of winding wire, and No. of turns for 30HP, 3 phase, 4 poles 50Hz, 380V induction motors

1481


The power factor of the fixed load is 0.8, now the p.f is varying from 0.8 to 0.5.

1579


3phase motor can be used as a Prime mover for alternator.

1177


what are factors to be consider in electrical installation like load factor,diversity factor .....

1366


why induction motors are rated at 0.8 power factor.

1534






how to calculate singlephase motor efficiency?

1733


how to decide choke rating for drive?

1887


1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.

2782


Define branch?

633


1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.

1288


Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?

1234


please send me last 5 year interview questions

1673


How to calculate capacitor bank size at a load 800kVA.

1175


can we synchronize star system generators with delta system transmission line ? and how ?

2313


If the rated speed of a d.c. Shunt motor is1440 r.p.m, which method of speed control would you suggested to obtain a speed of 1500 r.p.m?

697