1.generator rated as 1000 mva,11kv .8 pf what will 0.8 pf
will indicate?
1.max pf it can supply 2.min pf it can supply
like this 4 options there what is answer.explain

Answer Posted / sreenivasalareddy

I will deliver (generator design)800mw power wether it
running at .8 PF or unity pf

When Generator runnig at upf we should alert we should not
load alternator to its rated current

Because your out put power will become 120 % almost ,Which
is not design for this load (Primover)

As for as my concerned pf is restrited to protect promover
and alternater eigher way

Is This Answer Correct ?    5 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is different between resistance grounding system and resistance earthing system?

678


can we use trip light with bus coupler?

1434


SUTIABLE FOR ohm's law super conductor

1523


what id a dry type transformers and its function ?

1348


what is magnetizing and demagnetizing current in generator and motor?

2736






how does it help for selection of a transformer.

1363


I want to put this query to SENIOR & EXPERIENCED ELECTRICAL ENGINEERS. 1)I want to know about the control circuit diagrams for control panels. I found it difficult to understand. Is there ant booklet through which we can learn the circuit diagrams? 2)I want to learn about conduiting, laying cables, preparing cable schedules and various techniques which is the part of building infrastucture(construction field). I don't have any experience in this area. I have experience in control panels only. that's why i am not getting any opening in building infrastucture (construction field).Can I get the job in this field as Trainee Engineer? How to enter this field? I need job in PUNE

1487


in dc suppy frequency is zero why? if dc frequency is zero how to exist dc transients and ac transients

1557


2. Modify your design in question 1.a so that the circuit works according to the following function table X Y F 0 0 Clear 0 1 No Change 1 0 Parallel Loading 1 1 Count 3. Design a circuit that detects the pattern 010 in a serial input X considering: 3.a Overlapping 3.b No overlapping

1457


How we can calculate the consumption in kwh of motor on basis of kw @100% load, @50% load & @ no load.

2330


What products have you designed which have entered high volume production?

1583


How does "OUT OF STEP" relay ,for Synchronous motor protection, work?

3900


As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1199


i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test

1382


What is inductance?

672