Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to calculate the capacitor rating for improving power
factor

Answer Posted / r n seth

capacitor required is too be calculated from required power
factor to desired power factor.the formula is-

Req. Cap in KVAr= Tr. MVA* PF( tan cos-1(existinf PF- tan
cos-1(desired PF))

Is This Answer Correct ?    21 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How can eliminate noise problem inside temperature controller temp. variation due to contactor chattering problem.

1635


distribution is maximum done by a)radial b)network c) parallel d)b & c

2027


How To Convert Apparent Into Real Power Without Knowing Reactive Power?

1797


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity?

1981


ROC converges if poles and zeros lie inside a. Origion b. Z=1

2273


what is the power rating of CPU, CRT type moniter, LCD type moniter,scanner Approx.

2209


what shall be no load voltage of 132/33 kV transformer ? is it 33 kv of 34.5 kV

2192


explain comutator action in detail.thanks

2263


who can measure the size of power cable?

2168


whats the application of voltage regulation? and whats the voltage regulation's device?

1902


why electron produce magnetic field when it is in motion?

2157


We have received supplies of the ordered material. payments against the supplies also released. Where ST paid 4% against form C. Meanwhile it has been observed that 25% of material supplied was defective. Please suggest whether the issuance of C form from our side would be stopped till settlement of liabilities.

1965


how many safety really of DG sets.

2248


In HVDC LINE RECTIFIER CONTROL ON CONSTANT CURRENT AND INVERTER CONTROL CONSTANT EXITATION ANGLE CONTROL BUT HOW INVERTER CONTROL CONSTANT CURRENT?

1972


which are the criterias needed to select the kind of neutral earthing(solid earthing,resistance earthing,etc.) at various voltage levels in electrical distribution?

2001