Answer Posted / jayaseelan
usually torque is inversely proportional to speed in normal
application.
for particular application ony we can reduce the power
consumption ex.fans,extruder,pumps etc
Some loads have a Variable Torque characteristic, that is,
the torque increases with the speed.torque increases means
current increse also speed increases so if speed reduce
means torque reduce consquently current reduce this is the
concept.
usually torque is inversely proportional to speed in normal
application.but some cases ex.
Is This Answer Correct ? | 10 Yes | 6 No |
Post New Answer View All Answers
there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit
can anyone explain 11kV 3core cable megger,hi pot test procedure with connection details?
what is difference between 5A and 100A CT constructional wise and operation?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what type of earthing do for dry fissure rock?
What is the Surge suppresor? Why using in a UDB's and How it works?
please send me RRB electrical engineer previous year questions for Sr. Section Engineer
hi plz send me reliance placement papers..i.e electrical technical papers that have been asked in reliance test.
Why is back emf used for a DC motor? Highlight its significance.
How Can I calculate for the photometrics requirements for a street lighting? Data given are: 45 units of 6 meter light pole with 150 watts metal halide lamp, 220 volts and installed in a promenade area.
how to compare with Relay settings for HT< panels, RMU panel, and PSS CSS transformer?? 1) Load amps, 2)Tripping time, 3) CT ratio, 4)Cable size 5) Transformer KVA rating 6) transformer full load amps
how to select electrical equipment such as fuse,dg,transformer,motor,msb,wire,cable as per the connecting load..please mention any books to design,take licence
What is Fire Panel ? How it works ?
how to calculate kvar in Akiva
why magnetising curve not start with zero voltage?