What is the use of conservater, bucchos relay, breather in
a transformer?

Answer Posted / jayprakash

Buchholz Relay : Used as a protective device for
transformer against internal faults. If there is a fault
inside the transformer, due to heat gases will be generated
and trapped in Buccholz relay and will protect the
transformer.

Conservator : The transformer main oil tank is always
filled completely. During summer and heavy load conditions
the oil expands and the conservator is provided for the
expansion and contraction of oil

Breather : During contraction of oil, the outisde air gets
into transformer thru breather. The breather has silica gel
which absorbs the moisture. Also the breather has a oil cap
to stop entering the particles such as dust enter the
transformer

Is This Answer Correct ?    157 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is milivolt dop test in Busducts? What is its significance & procedure to do the test?

1587


i have faced a problem in ro plant grunfos make bm30type pump it is 22kw pump. We start this pump using siemens 3rw 4423-ibc44, 30kw softstarter but this soft starter will frequently failier so we planed to change dol starter. So pls tell anybudy its possible or not.

1548


What is the Difference between Ac Drives and Dc Drives? According to application, speed, Torque, cost, Reliability, Construction, Motor etc... Thankyou !!!

1676


What is the Nyquist criterion regarding control systems?

663


advantage of motor design on higher power factor . normally motors are designed for .8 power factor. what is advantage of designing at .88 power factor

1398






Is a direct shorth ciruit on a branch MCCB in a Low Voltage Switchboard a correct means of tesing the performance for discrimination?

1768


Define conversion efficiency of a power amplifier. What is its value for class c power amplifier?

790


which book to refer in electrical engineering for iocl exam & which book for general english.

1769


A car's starter motor draws a current of 100 A at 12,0 V when starting the engine. The mechanical power required to turn the engine is 960 W. At what rate is energy from the battery converted to non-mechanical forms of energy?

1628


what is the easiest method of short circuit current calculation ? pls. derive with a mathematical example in real life application.

1975


132/6.6πš”πšŸ πšπš›πšŠπš—πšœπšπš˜πš›πš–πšŽπš› πš—πšŽπšžπšπš›πšŠπš• πš‘πšŠπšœ πš˜πš—πšŽ πšŽπšŠπš›πšπš‘ πš™πš’πš πšπšŽπšπš’πšŒπšŠπšπšŽπš. 𝙸'𝚟𝚎 πšŠπš—πš˜πšπš‘πšŽπš› πšπš›πšŠπš—πšœπšπš˜πš›πš–πšŽπš› 𝚘𝚏 6.6πš”πšŸ/415𝚟 πšŒπšŠπš— 𝙸 πšŒπš˜πš—πš—πšŽπšŒπš πš—πšŽπšžπšπš›πšŠπš• 𝚝𝚘 πšœπšŠπš–πšŽ πšŽπšŠπš›πšπš‘ πš™πš’πš 𝚊𝚜 𝚘𝚏 13/6.πš”πšŸ πšπš›πšŠπš—πšœπšπš˜πš›πš–πšŽπš›?? π™Έπš π™½πš˜.. πšƒπš‘πšŽπš— πš πš‘πš’??

579


Is a d.c.compound motor is use as a booster? how?

1661


Classify milling machines.

658


How to decide whether A / B / C / D curve type MCB should be used?

1857


Keywords: Die, Card, Coin, B/N 2 To 12

807