Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What would be the ratio of a Delta-Wye tranformer having
48000 volts phase to phase on the primary and 4160 volts
phase to phase on the secondary?

Answer Posted / k.babu

For Step down purpose

Is This Answer Correct ?    0 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why increase in current leads to increase in conductor temperature?

1141


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm

2288


In constant power region of 3-phase IM torque-speed characteristics, if frequency increases flux A does not alter B decreases C increases D none of above

2251


DG Earth Value?

2317


If a rotary UPS is in line through grid power; What would be the impact on Power Factor if the load through rotary ups is 25% , 50% , 75% & 100%. Will the power factor reduce with less load?

1883


How earthing of switchgear system to be done.

1934


State uses of different types of stsrters with different capacities of motors as below: a. up to 5HP b. above 5hp to 10hp c. above 10hp to 20hp d. above 20hp

2088


what is power factor ? how we can calculate the low power factor and amount of capacitor for improve that low factor ?

1622


solor panels arrange some angle,panel is flat fitted energy was produced or not why?

1907


why it is not advisable to run low rating (19KVA) DG sets in parallel for long durations even though they are provided with droop ckts (QDC)

1910


Salient pole alternator is more stable, why?

2717


Which capacitor is preferred for high voltage and frequency?

1086


what are the tests comes under the type test, what tests comes under routine tests.

1474


Two bulbs of 100w and 40w respectively connected in series across a 230v supply which bulb will glow bright and why?

1059


why are distributed windings generally used in alternators?

2730