For testing 33kv cable hipot testing. How much kv we have to
Apply .Give in details.

Answer Posted / ttrrail

AS HI POT TEST IS CONDUCTED IN DC, 25 KV SHOULD APPLY TO
THE 33 KV CABLE

BECAUSE

33KV X 0.707(RMS VALUE TO AVG VALUE CONVERSION) = 25KV(OPPR)

Is This Answer Correct ?    28 Yes 89 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are two contours of nichols chart?

627


why transmission is only 3 phase and not 2 or 4 or poly phases

1710


WE know that for Inductor X=2pifL,In DC f=0,then X=0 so,V=IX=0;But In the DC excitation of rotor of AC generator,DC motor field coil which coils are inductor so why does not applying DC voltage short the rotor coil of AC generator and field coil of motor?If it would then DC source might be damaged but it is not happened. Why does the strand conductor of Electrical power transmission line make twist?

3820


Why does the speed regulating system adopting I controller have no steady-state error? In this single closed-loop speed regulating system, when the input of the I controller Un=0, what is the output voltage of the regulator? What factors do the output voltage depend on?

1424


As i want some model question paper in basic computer science and history please send me immediately sir

1444






im electrical engineer, could any one help me for FEWA exam questions please ?

569


what are the principles of a booster converter?

1579


what is the solution for meger test failed the MV cable?

3538


How you calculating the 30 Hp 3 phase AC motor of power what size of cable is used for this motor?

1157


how to calculate regulation constants for over head lines? and what are the regulation constant for raccoon conductor at different voltage level and different P.F?

1469


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

975


what parameters should we check to reduce the power bill

1842


how copper and aluminium wires or cables are choose for current rating? please provide copper and aluminium wire selection chart for different current rating ?

1580


Describe Non I.S. Earth System and why is it used?

1299


What are hrc fuses and where it is used?

739