Answers / { baskaranpillay }

Question { 3788 }

how to save the power?


Answer

there are so many many ways to save power.the best and sure
way is not to use power, other than that simple studies must
be carried out first to know where we are using power to
save them.Lighting is an area where every one
uses,unnecessary brightness or misuse can be avoided types
of lighting material can also determine power
consumption.Air conditioning is another area where often
abuse and misuse takes place.likewise look around where and
what are u using power for,to save.

Is This Answer Correct ?    1 Yes 0 No

Question { Bhel, 10255 }

what is the formula for calculating of dielectric strength of
transformer oil.


Answer

There is no formula.A carefully collected sample oil is
tested in a specially designed tester.

Is This Answer Correct ?    6 Yes 4 No


Question { 3947 }

what is formula of dc current and resistance.


Answer

Use the ever useful OHMS Law.

Is This Answer Correct ?    1 Yes 0 No

Question { 3137 }

why the star delta motors burn out frequently


Answer

I have not had this problem all this while anyway for a
motor to burn out running on star delta starter must have a
reason like
too heavy a starting load
quality of winding after rewinding
contacts of starters
starters itself including timers and o/l relays

Is This Answer Correct ?    1 Yes 1 No

Question { ABB, 4971 }

What is the Relation b/w star delta starter , DOL starter and
two speed starter.
if we want to rotate a 20 kw fan in 2 speeds which type of two
speed starter we have 2 use?


Answer

All the starters you have mentioned is for starting and
running the motor. DOL starters are usually used for smaller
motors where the starting current will not affect the
distribution system or the motor itself or the connected
machine, wheres star delta starters are used for bigger
motors and where the winding terminals are available for
such starting, whereas the two speed starter can be only
used if you have a motor with two speed windings.
If your 20kw motor comes with two speed termination than you
can use the two speed starter if not than you may use
inverters where by selecting the frequency you may vary the
speed of the 20kw motor

Is This Answer Correct ?    4 Yes 0 No

Question { IBM, 3473 }

why do star-delta connection ?
why do not connect any circuit direct connection ?


Answer

when the motor is started on star only about 60% of the
full voltage is applied across the motor winding. So the
current used is reduced but enough to start the motor with
the load.Once the motor picks up speed the current used is
reduced further, than the connections is changed through the
starer contactors to delta where the full voltage is applied
across the windings to enable the motor to function fully at
its rated voltage.
so the motor is started star and than run delta to reduce
the starting current.

Is This Answer Correct ?    7 Yes 0 No

Question { 5519 }

what is the difference betwteen overcurrent and short
circuit fault?


Answer

As the name imply over current means over loading which can
be for a very short time like when switching on a heavy load
or just overloaded slightly by 10 or 20 %.

Short circuit faults are usually of high magnitude when
there is a fault like cable fault or equipment fault.

Is This Answer Correct ?    9 Yes 1 No

Question { 14786 }

What is mean by making & breaking capacity of circuit
breakers?


Answer

making capacity of a circuit breaker means when you switch
on the breaker the breaker can operate safely or withstand
upto the stated amount.

The same applys to breaking capacity of a breaker which
means when it switches off it can withstand up to the stated
amount at the time of offing. The unit used is usually KVA
or MVA.
Some breakers can have a high breaking capacity but a low
making capacity. This means when switching on it should not
be loaded but can be switched OFF with a high load.

Is This Answer Correct ?    12 Yes 7 No

Question { 4635 }

how to reduce the initial starting amps which is equal to the
running load amps


Answer

It depends on what type of load it is carrying,any way with
the use of variable frequency drives one should be able to set
the starting current to the desired level if the load
provides.

Is This Answer Correct ?    0 Yes 1 No

Question { 6234 }

why should be the frequency is 50 hz only why not others
like 45, 95 56 or anything ,
why should we maintain the frequency constant
if so why it is only 50


Answer

You can have the frequency at any frequency you like,
but than you must also make your own motors, transformers
or any other equipment you want to use.We maintain the
frequency at 50hz or 60hz cos the world maintains a standard
at 50 /60hz and the equipments are are made to operate at
these frequency.

Is This Answer Correct ?    5 Yes 0 No

Question { 3003 }

if a 3phase 100kva distribution transformer , 400 v,50
hz, 4-wire system is loaded at 160 k.w mostly 1-phase
Lighting & Airconditioning split a.c load what will be the
net effect on the power system in terms of voltage,
powerfactor, current , efficiency of xformer


Answer

how is it possible to load a 100kva xformer to 160kw? this
is abuse & blatant disregard of all safety for equipment and
life.Anyway if it is loaded as such than all your question
would be answered by the power formula if you know the constants

Is This Answer Correct ?    4 Yes 1 No

Question { 3238 }

can we run the home fan both clock and anticlockwise direction


Answer

You can, if you can bring out the connections to a forward
reverse switch.The fan is usually a cap run connected motor.

Is This Answer Correct ?    5 Yes 2 No

Question { 12404 }

why the autotransformer burnt while stating the pumpmotor?,
In starter and motor there was no abnormality.


Answer

a)Loose terminations at the auto transformer itself .
b)intermittent failure of the change over timer or starter.
c)excessive load at time of starting .
d)insulation failure of the auto transformer.

Is This Answer Correct ?    9 Yes 1 No

Question { 5753 }

TYPES OF TEMPERING OF ENERGY METER


Answer

Anybody can temper an energy consumed meter if you know how
it works but it is plain cheating. No society condones cheating.

Is This Answer Correct ?    6 Yes 5 No

Question { 3106 }

i want the formula of total eletical knowledgement


Answer

Enroll in a reliable college for a course in electrical
technology.

Is This Answer Correct ?    0 Yes 0 No