Electrical Engineering Interview Questions
Questions Answers Views Company eMail

A current of 2A flows for 10 hour through a 100 ohm resistor. The energy consumed by the resistor is:(a) 0.5 kWh(b) 4 kWh(c) 2 kWh(d) 0.02 kWh

3 12483

The unit of quantity of electricity is the:(a) volt(b) coulomb(c) ohm(d) joule

1 2570

Electromotive force is provided by:(a) Resistance’s(b) A conducting path(c) An electric current(d) An electrical supply source

2 4062

The unit of current is the:(a) Volt(b) Coulomb(c) Joule(d) Ampere

2 2533

In order that work may be done:(a) Two wires are necessary(b) The circuit must have a switch(c) Coal must be burnt(d) A supply of energy is required

1 5836

The ohm is the unit of:(a) Charge(b) Resistance(c) Power(d) Current

2 2062

The unit of resistivity is:(a) ohms(b) ohm millimetre(c) ohm metre(d) ohm/metre

4 3168

Voltage drop is the:(a) Maximum potential(b) Difference in potential between two points(c) Voltage at the end of a circuit(d) Voltage produced by a source

3 5749

what is earthing transformer? draw the winding dia.of earthing transformer.

1234

why capacitor offer reactance to alternating current?

Electrical,

1 2153

Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1354

How to calculate the breaker's short circuit current?

1 3061

how to calculate efficiency of voltage and current controlled welding transformer?

1 2155

How to check the thermocouple is correctly connected to cable for K type? (i,e positive pole is connected to non magnetic conductor and negative pole is connected to magnetic conductor)

1248

Rccb trip or not with out neutral connect in three phase welding machine

1 3319


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

how to calculate the fault in substation

1708


What happen when neutral point connected to core balance current transformer? (Neutral point of an alternator of a 180KVA DG. Neutral point connected to CBCT means enter to the CBCT)

1836


I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?

2041


A logic circuit that provides a HIGH output if one input or the other input, but not both, is HIGH, is a(n)?

667


Incoming line 11kv And transformer capacity is 2500kva. Consumption load is 1300A. Then fuse capacity is 11kv line.

1257






How to calculate no of EARTH PIT? Describe the formula as per IS standard?

3182


I have doubt that the supply HZ (very low or high than rated ) may affect the power factor. is it true. ?

1210


Connection diagram for KW meter and  Kva meter

1779


what is reactive power?, why its measured in VA ? is it transient behavior of system?

1789


What is the difference between relays and contactor construction wise?

1604


when we decide to use soft starter drive or vfd drive in mcc to operate apump?

1530


please send me last 5 year interview questions

1661


How to calculate per unit impedance of transformer?

1559


from which formula we select a capacitor rating?

1614


describe the A.C. Generator Testing procedure

1638