Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT

2110

How to calculate approximate load loss of a distribution transformer by knowing %ge imp of transformer?

1737

WHAT IS M.P.C.B

3 4773

what is the acb tripping & closing voltage.

2 3598

what is difference b/w bus duct & bus bar.

2 4635

what is the difference between ups & inverter

Cushman Wakefield, Dana Group,

4 5474

what diff. between earth nd neutral?

NTPC,

3 6901

Which generation plant has instant start

2 3691

what is the eight bit unit?

1961

If you have an earth with pilecap then your resistance is really low. why and how?

1430

if i get a drop in my 1st year and the i clear my 2nd year and 3rd year all clear and i dont have any back logs so can i be able to sit in campus selection??

1368

while selecting transformers for 33 kva feeder normally we ask for 33/433 kv why not 33/415

1 3073

what is the formula of high voltage testing of three phase induction motor?

1 3326

what is the rating of Insulation tester for measure 15 KW, 3 phase 415V 50 HZ induction motor?

ABB,

2 5160

What is diffrence bitween electrical and electronics ?

4 4140


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

What is fault clearing time for Current Limiting Moulded Case Circuit Breaker?.

1316


What is the de rating factor of cable? What is the importance of the de rating factor in cable select

1879


Why the dc voltage drop during starting of emergency lube oil pump? The Voltage drop from 135kv to 125 kv for one min. before re-establish to 135kv?

1788


What is the function of the circuit breaker failure relay?

1890


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1439






what is the AC Plant and how can do the work with parts and picture tell us 150 Tr

1541


which mm cable should be used for 1.hp immersible pump motor for the distance of 330 metres?

1245


WHAT R THE SAFETIES IN A HIGH TENSION PANEL N LOW TENSION PANEL. ALSO WAT SAFETIES R THERE IN A 200 KVA TRANSFORMER?

1811


how to wiring it with contactor and timer together

1342


How to set the relay,,??

1619


Define conversion efficiency of a power amplifier. What is its value for class c power amplifier?

777


surge tank, hrc fuse, earthing transformer, firm power objective type

1107


generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...

1534


what is the difference between Power and Distribution transformers ?

1630


A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.

2067