Electrical Engineering Interview Questions
Questions Answers Views Company eMail

can we run the home fan both clock and anticlockwise direction

1 3232

in star connected 4wired transmission system ,what happen if the neutral is grounded . or not grounded. which is significant and y

2 3673

if we have to design a small transformer of rating 1 kva or 1 mva , how can we design it?

1 3719

What is highest size of HT motor like 11 kv or 33 kv,and how to make it 750 rpm.i think the size will be very big.any idea ? pl. reply..

ABB,

1503

Is it required to lay 2 runs of GI wires along with armoured cables from one power DB to another Power DB?

1474

Is it required to lay GI wires along with GI/MS conduits from one point to another point though separate earthing cable is conncted from DB to Socket?

1535

Is it required to lay 2 runs of GI wires along with armoured cables from one power DB Machines of higher rating?

1557

Is it required to do earthing in 2nd shop if earthed armoured cable is laid from 1st shop ?

1435

What is the max value of neutral current that can be allowed in system?

1699

What are the disadvantages if neutral current exists in grounded star transformer distribution system?

1 4780

What will be advantage if we put some load in neutral of grounded star transformer & loadshortcircuit current,rated current of cable & MCB with example?

1412

What will be the size of cable required for 5.5 KW motor ( Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.

2 25280

What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.

1583

What is the difference between LT CT & HT CT?Can we use indoor type transformer as an outdoor type or vice versa?

Bhel,

2 10159

Where can I get CPWD electrical specifications & Shedule of rates? Please help me

1812


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

How to calculate main incomer rating of APFC Panel ? Let's say i want to find main incomer for 11kV, 1000kVAR Panel.

1231


is ac supply can store

1514


plz tell me,ht and lt panel terminals in substations explain beiefly

2342


What is a system?

691


I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing

1316






How to know Resistance and Reactance value of main and aux winding of single phase capacitor start capacitor run induction motor to find capacitor value?

1503


IF HT CAPACITOR IN ON POSITION IS THERE ANY LOSSES I.S I SQURE OCCURS IN THE SYSTEM

1599


If I have Energy Meter Ratio as 100:5 & Also I have CT Ratio as 50:5 then what will be my multiplying Factor(M.F.)

1541


how many joints are allowed in underground HT cable of 1 KM

1362


Anybody tell me about modbus hex address of l&t trivector meter er300p??I want to read voltage,current,kwh etc via rs485...If anybody have a manual then send on my mail..Brijeshmodi18@gmail.Com

1267


can u please mail me the syllabus for GET exam for damodar valley corporation?

1601


I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)

1451


The gauge indicates the number of amps, but what about voltage? How voltage rating (for wire or fuse) determined?

1518


what is your majour contributions in your present job

1342


if grounding is notdone at regular intervals for long distance transmission, will the load connected at distribution end receive voltage during negativehalf cycle of the sine wave?

1548