Electrical Engineering Interview Questions
Questions Answers Views Company eMail

Which one is given high energy in same power consumption AC or DC

Dhyey Creation,

1 1989

Why we specify TNC switch with 1NO 1NC ,2NO 2NC ? how we get connection.?

1257

Why in power plant projects we see DOL starting method used for motors upto 160 kW instead of star delta method

UCC,

1369

How to earth the star delta connected transformers?

UPPCL,

1 2115

In a synchronous motor. if start is running at high speed.  What will be the starting torque : Higher Lower Zero

1237

in the farm,water tank of 8000 litter capacity situated in 12 meter above.Farm owner want to lift 7000 litter of water within 7 minute to water tank of 12 meter above.which motor having HP rating is suitable for pumping??

ABB, Anchor, Havells, Keltron, KSEB, L&T, vguard,

1 2243

How can we measure the residual voltage in dc machines?

GPREC,

1210

why the neutral line is not giving shock to us if we touch it ?

GPREC,

1330

we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan

RYK Mills,

1213

Define the "All - Day Efficiency" of a Transformer

Transco,

1 2505

Which colour of earthing wire

Aravali,

1 1879

We are dealer in Maharashtra State & We have recd. form C from dealer of Maharashtra State against our E-1 form. Now assessing authority is asking for counterfoil of our E-1 form. But, our E-1 form counterfoil is misplaced somewhere & assessing authority is disallowing the C form which is recd. from Maharashtra State.Please let us know the option for allowing C form?

1 1744

How to know the Max. current caring capacity of the cable by its size ?

SFPL,

1164

How to work definite,over pluxing,revers power,OSR relay

Ford,

1235

What happened if C.T mount at any cable or Bus bar in wrong direction . C.T going on proper work or not . C,T direction is essential thing to properly work.

1237


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

How can we measure earthing resistance test (Earth meggar) of Transformer neutral pit while in live condition?.

1626


What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?

1333


Why armature rheostat is kept in maximum position?

630


why we testing the core balance of the transformer before comissioning?

1566


how much value of resistance should connect to 15 kw, 6 pole 3 phase slip ring induction motor having RV-240, RA-42.

1444






High speed earth switch operation with diagram

1875


why the electrolyte level in lead acid battery is maintained 2.5 cms above electrodes?

1393


for what purpose the star point is done in ct

945


What do you mean by a phase angel of instrument transformer?

630


Explain the operation of variable frequency transformer?

662


what is electrical machines

3000


what is effect of length of air gap on performance of dc motor and generator?

1327


what is the formula for hv test for cable and circuit breaker..????

1528


Why does the speed regulating system adopting I controller have no steady-state error? In this single closed-loop speed regulating system, when the input of the I controller Un=0, what is the output voltage of the regulator? What factors do the output voltage depend on?

1409


from which formula we select a capacitor rating?

1611