how to calculate voltage regulation?

Qtech Software,

1 2048

if negative of DC supply used and positive is grounded through EGB, and if ELCB used in the system then is it sense the positive volatge and get tripped is it possible?

Delta,

1273

why should small green grass ans small plant should not be there inside the transformer Yard in the factories

Riddhi Siddhi,

1202

why a tester wont shock while testing the power in house

Tessolve,

1315

i have a 1500kVA transformer what is the kWH meter i need to use?

HP, L&T, Mohammed Harasani Architects,

1191

Is necessary Protection CT, CLASS - 5P10 fitted at Incomer side of main Breaker ? Why ?

1 1753

What type interview questions ask in Electrical technicians

1258

ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?

1506

Hi, I'm running plastic reprocessing company where all motors are running only in delta. Due to that when I use start my 30 hp motor my transformer gets fuse. Where it happens two times a day. I gt a suggestion from a person about Automatic Power Factor Controller APFC. Is it useful for my problem??? Or is der any other way for solving this problem?? Upgrading the transformer is difficult. Pls give Me ur suggestion. Waiting for ur reply.

Shree Lingaa Polymer,

2 2041

V.c.b and a.c.b difference

4 2929

why Lightening Arrester Probe sharp at Top of telecom tower.

Reliance Jio,

1088

What is the meaning of loop in transformer

AST,

1187

can we use NPT glands in LT panel

1318

If our power factor is lagging then who is in profit? I mean consumer or Supplier!

Sail,

1 2075

What is the unit audit? if our Max demand is something and we found much more unit then how to improve our max demand?

SRM,

1508


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Why LED light has advantage of rapid reflection ,although other lights alse reflect.? and this light is considered to be best for transmission usage in case of Free optics

1578


Cb closed condition if there is a tcs fail whether cb will trip or not

1311


How to calculate the phase to phase clearness of HT /// LT bus bar?????

1579


What is the direction of current flow in ct secondary...means if the current is flowing from P1 to P2 then what will be the direction of current flow in ct secondaryw

1405


The Q-facr o of a coil given as wL/R. what will be shape of Q versus frequency graph.

1543






how can i find cable size from current rating?

1316


HOW can i REuse the fused MLL LAMPS & GLS LAMPS at our factory

1417


What is meant by vector group

1969


What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?

1333


how to read idmt curva

1709


Why reactors use before incoming of ac vvfd drive?

1357


What are the two types of compensation?

616


Pl.brief me about Electrical power distribution system from Main generating station to Industry.What is the use of in between station.

1584


How to calculate approximate load loss of a distribution transformer by knowing %ge imp of transformer?

1737


What is mean by Sensitive Earth fault & what are the effects

3740