What is the journal entry for goods sold to Mr A in 1 month credit of rs 5000. and also pass entry for non repayment of money after 1 month by Mr A. (What entry will come for this?)

3 12572

Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.

2021

what sq.mm copper pvc wire need for ac load current 25amps for 230v ?

4 6497

What is purpose to use relay after digital output module? Why normally we don't use relay for digital input module?

3 7058

how to calibrate load cell

2311

is earthing is necessary if we use armoured cable

1 4894

What are d uses of a diode . What is diode equation . And what is its use

2 6178

what is mean by dry frequency

1932

how is the testing of an REF relay? what are the test REF circuit having?

1450

We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1659

Is there any problem about which the drive (inverter) doesn't show/display the alarm and/or fault but instead of this , it doesn't work ? I want to know that could there be any kind of problem in the drive when the drive doesn't display the alarm and/or fault ?

1506

What is mean by spike arrester(Voltage Operated)

1600

I have AC automatic voltage regulator 15KVA What output currant?

3 4470

Can we calibrate an actuator?

5 10841

why transmission voltage is 230kv and not 220kv which is a multiple of 11

1 5481

Post New Siemens Interview Questions


Siemens Interview Questions


Un-Answered Questions

When is retroactive accounting used?

506


What is hibernate query cache?

190


Do you know someone working in Amazon?

709


Explain res folder in android?

477


How can you import only a subset of rows from a table?

5






explain about completely flow of sequencers technicaly,without using example??explain about lookup,nullhandling?

1920


why airtel use + 24 volts and other operators use -48 volt

2103


In a single process non of user's are accessing Web site when i checked the logs it showing event ID "530" ? need the solutions and also Mail me all the event id's related to IIS...

1660


What is a backing bean?

62


What is cookie less session?

565


How you can differentiate between conversion operator "todictionary" and "ienumerable" of linq?

64


You know that BAC = 375, PV = 300, AC = 200, and EV = 250. Variances that have occurred on the project to date are not expected to continue. What is the ETC? A. 75 B. 50 C. 125 D. 150

847


Why constructor is not overridden?

538


What is qualification testing?

689


What are psrs?

595