Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why Transformer in KVA?

Answer Posted / dileep

Because transformenr is used for converting voltage level
only and nothing therefore its rating is in KVA i.e. KV x
Amp It gives us rating/capacity of transformer how power it
can handle.
The equipments not meant for consuming power are rated in
KVA units & those consuming power are rated in KW.

Is This Answer Correct ?    16 Yes 68 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why is using sensor?what is differece between photoelectric and proxmitty?

1998


What is dynamo function in DG sets and draw block diagram?

2033


what's the difference between abs/inc encoders. apart from the position remembrance what are all the other differences. and what's mean by grey code.

2078


advantages and disadvantages of inverse definite minimum time RELAY

1553


WHAT IS SPEC OF CLEANROOM MOTOR AND LIGHT FITTINGS?

2311


can someone explain that how the speed of the protection system affects the fault level calculation?

2074


What is the function of NER and NET?

2434


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2149


what is the differance between HT motors And LT MOTORS.

1974


Form S and "c" license application both are same? @ tneb portal

1831


what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY

2197


What are the basic elements used for modeling mechanical rotational system?

1103


what is spadar bar .why I use in DC generator.

1916


The Q-facr o of a coil given as wL/R. what will be shape of Q versus frequency graph.

2014


Please tell me the earthing procedures adopted for the STAR-STAR 3 Phase transformer in india and give a better sugession for earthing

1951