Answer Posted / praveen kumar (ipca_ranu)
Melting range:- Refers to the temperature range over which a substance begins to melt and completely liquefies. It is a broader range of temperatures and is typically observed for mixtures or impure substances
DSC- Differential Scanning Calorimeter (DSC) measures temperatures of a reference material and a sample while changing the sample temperature in accordance with a program, and then measures the amount of heat from the temperature difference.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?
Why are use silicon oil mr?
Difference between hlaf and rlaf
What is intact assay method development.....?
inhouse product is in capsule form in combination and RLD is in tablet form then can we proceed for multimedia CDP? in inhouse capsule product disso is paddle with sinker in release media is there then RLD product in tablet form then with same as paddle with sinker we can proceed n.a.?
What is the difference between spectro meter and spectro photo meter?
Tell me something about Vitamin A test method by HPLC
please explain about aluminium hydroxide assay
In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?
WHAT IS THE PARAMETER FOR THE SELECTION OF MOBILE PHASE IN HPLC?
what is definition of validation? which components are followed give detail?
some product having water content method with pyridine and ethylene glycol mixture instead of methanol? how they are selecting and methanol is not suitable solvent how ?
I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?
If vendor having more imp than monograph then how to proceed? and how to set spec?
IS THERE ANY EQUIPMENT TO CHECK AND CALCULATE THE POLARITY OF A LIQUID?