Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

%lod always grater than %water content for same product??

Answer Posted / krishna vankalapati

%LOD always grater than %Water content, because while performing the LOD residual solvents and water content will loss by heating.
Where as while performing the water content measure the water content only.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is third integration

1989


Why we check moisture,ash & AIA in product

1895


in gas chromatography what is the difference between gas flow rate and average linear velocity ?

2610


While performing TOC sst analysis Zero shift disabled & sample analysis zero shift enabled why?

2874


identification is for unknown? qualification for known? reporting for LOQ?

730


how can give the expiry period and restadardisation of volumetric solution

2601


Hi sir if any product monograph not given known impurities (may be 5 impurities) specifications then how we require to proceed for inhouse formulation?

708


what is the purge flow & how to calculate

2656


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

932


what is different when impergnated silica plates are used in separation of azo dyes using column chromatography?

2033


How do we fix the sample concentaryion in hplc method development. What is the basis?

1214


i want model written test paper for the post of analyst in IOCL(indian oil corporation ltd) any one pls help me

2739


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3671


What are usp limits for theoritical plats,resoution,tailing factor,peak to valley ratio

1902


If suppose 10 methods of dissolution given in pharmacopoeial for single content product then which method out of 10? or all 10 require to follow?

1001