Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to decide the standard concentration for related substances hplc method

Answer Posted / deepakshewle84

Std con is decided on the basis of identification threshold mentioned in ich. Eg. Your sample concentration is 250ppm & identification threshold limit is 1.2% ans is 3ppm.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHY pKa value is more important than pH value of the mobile phase in HPLC?

1755


how to selecet an exact coloumn for an new molecule development by hplc how to select exact salt as buffer for new molecule development by hplc what is the the process to select the mode of saparation of compoundes by hplc what is the use of ph of buffer what is use of buffer,ph,organic phase,ans methods how the molecules get saparated in coloumn,

2590


why we use glass fiber filters use in some situation?

781


in gas chromatography what is the difference between gas flow rate and average linear velocity ?

2589


Which is the highly polar and highly non polar column in HPLC?

2295


How you develop a method in HPLC?

2608


What is the diference between residual solvents and organic volatile matter

2019


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1587


how to calibrate hplc & gc

4496


Qc interview questions

1733


As per ICH related substances stability trend limit from initial to shelf life

3242


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3161


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

767


How doing qbd practically?

958


What is mean by PDR?

934