Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How can we konw that the HPLC column is endcapped? Is it
possible to identify visually without COA?

Answer Posted / dharmesh bhatt

visually not possible unless one can try on the system. but another way is to check in the column literature which is now easily available on net. or can ask the same to column supplier.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the primary considerations in extractables and Leachables ?

2261


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1794


How to set analytical specification for combination products?

812


What is similarity factor?

1185


Why to use propyl paraben in HPLC gradient calibration

7419


What is the difference between spectro meter and spectro photo meter?

11452


if tech transfer fails whay require to do?

823


If we do accuracy at same concentration at which linearity planned,what is the need to do linearity separately?

2282


Why only Copper standard is used to calibrate Atomic Absorption spectrophotometer?

2715


How can we confirm the HPLC column is end-capped or not? Is it possible to identify by physical appearance?

3196


WHICH STANDARD WE USE IN SILICA ANALYSIS IN SILICA-GEL METHOD FOR SOLID SAMPLE

2115


please explain about aluminium hydroxide assay

1117


what is %labelled amount in content uniformity of dosage unit and its calculation?

5198


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

3852


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1580