Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is primary & Secondary Standard ? Give Example

Answer Posted / aatika firdous

Primary standard is a compound of sufficient purity from which standard solution of known normality can pe prepared by direct weighing of it and diluting to a defined volume of solution

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1900


what is the disso medium for tropsiun chloride

2311


How to fix the sample conc. in Related substances test by HPLC?

1142


What is the requirement for brazil in the analytical method vslidation comparr to ich?

849


why does used dry caffien in HPLC calibration?

2078


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1651


EXPLAIN THE CALCULATION PART OF AN KF TITRATOR CALIBRATION WITH SUITABLE EXAMPLE

2685


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

906


if your impurity coeluting with each other in that situation how require to set specification? is it acceptable?

1042


How require to develop GC method? how to select diluent, GAS, column selection and other chromatographic conditions?

791


If suppose 10 methods of dissolution given in pharmacopoeial for single content product then which method out of 10? or all 10 require to follow?

1040


Home heating oil or furnace oil what is made from? Can (base oil plus diesel/kerosen) = home heating oil?

2229


UV and PDA detector, which have less signal to noise ratio?

1177


sop of a uv visible spectrophotometer double beam elico model

5989


how can I make the copper get white bye any salt or acit?

2264