Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why sucrose used in polarimeter calibration?

Answer Posted / s.ramakrishna

sucrose does not give mutarotation,it gives stable optical rotation.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3485


For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?

2259


IS THERE ANY EQUIPMENT TO CHECK AND CALCULATE THE POLARITY OF A LIQUID?

2389


What is the acceptance criteria for moisture balance when calibrated with sodium sulfate

1985


Why we used in n-butyl acetate water content terminology while in ethyl acetate we used moisture content terminology?

1794


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1741


Which products will produce when acetic anhydride reacts with Ter-butanol, Sec-butanol, Iso butanol, Dimethylamine etc.

2827


effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

841


how require to fix the linearity and accuracy cincentration range?

1565


In Dissolution Test why limit is define Q+5% what is the role of +5%.

3041


give clarity of linearity and range in method validation

2373


what is mean by covalidation

730


what is the origin to prepare standard operating procedure

2246


when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

1984


Principle of single pan analytical balance

5082