Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we are using only lead standard solution for Heavy
metals test? what is the purpose of this?

Answer Posted / sandeep

In production mostly we are using GLR and other equipments most of them come up means coating with lead so while in the reaction there is a chances of leaching of lead may takes place that is why we are using mostly lead as a std in HEAVY METALS testing...

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3542


How we performed the force degradation for drug substance, is any specific guideline is available for each parameter(Acidic, basic, oxidation,heat)? what conditions you mentained for above parameters.

2313


why salisylic acid not using now days for disdolution calibration?

779


how we can identify the impurity is coming below loq at transfering site?

875


How to establish relative response factor for hplc. Why it is required?

1233


Tell me about analytical method validation in QC

6184


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1603


What is delay volume?

1399


WHAT IS THE USE OF STARTER ?????????

2431


what is the structure of DOWEX-50

5521


What should be the level/ Percentage of Arsenic in Arsenic free zinc.

2233


Difference between hlaf and rlaf

2116


What is control room temperature and which guide line says?

1648


How to set analytical specification for combination products?

824


For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?

2319