What is diffrence between residue on ignition and sulphated
ash?
Answer Posted / ajay ram jayswal
Residue of Ignition and sulphated ash has no more difference except the fact that sulfuric acid is added when sulphated ash is done and in residue on ignition no such chemicals are added before ignition.
However the question is, which one is better testing method for finding any kind of impurities.
Not much but if we go through the theoritical facts, residue on ignition will be better choice. To support the fact,all the impurities that remains in residue on ignition test can be tested . But when sulfuric acid is added in sulphated ash , only the sulphate counterparts or sulphate related reaction product wwill be detected.
| Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?
For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?
If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?
Loss of linearity in tkn analysis, possible reasons?
how to selecet an exact coloumn for an new molecule development by hplc how to select exact salt as buffer for new molecule development by hplc what is the the process to select the mode of saparation of compoundes by hplc what is the use of ph of buffer what is use of buffer,ph,organic phase,ans methods how the molecules get saparated in coloumn,
How to calibration of the uv spectroscopy and its test?
WHY given much noise PDA dector then VWD Dector
in monograph 7 imp are there but in vendor showing 5 imp do not req to include 2 imp for that what will be justification?
Why we use potassium dichromate in uv calibration Exact reason behind it??
from where i get mortar pastle for glass bottle crush? it's required for testing of it?
For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?
What is column in chromatography?
Why sometime potassium ortho phosphate mix with acetone use for sample preparation for hplc
what is mean by extactable and leachable study?
In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )