Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why nearly all the voltage levels are in the multiples of 11
like 3.3 ,6.6 ,33 ,11 kv.....

Answer Posted / k.sahadevan nair

In India and other commonwealth countries, in the initial stage maximum generation voltage was 11 KV considering maximum available insulation rating. In order to step up this voltage,secondary of transformers should be 33 KV, 66 KV, 110 KV ,132 KV, 220 KV etc. So HT voltage of all step up/down transformers were fixed at multiples of 11. This has become a practice. This has nothing to do with form factor 1.11
When generation voltage is improved due to advancement of technology it has become difficult to change rating of all existing transformers. Naturally rating of transmission voltage of multiples of 11 continued and still going on. This is not applicable to EHT as this is a recent development and limited to certain countries only.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the basic rule for block diagram reduction technique?

1320


A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.

2007


sir i have a car stereo system and there is jack on him so can u tell me a way to find out their power terminals on the jack or on the circuit board"

2099


what is the difference b/w UHVDC and HVDC(LIGHT)?

6919


For overhead protection we use which transformer?

2548


Explain how you intend to work under pressure to meet up with deadline target?

5268


please send the last 5 years {{{JUNIOR ENGINEER - ELECTICAL, ELECTRONICS RRB CHENNAI and secundrabad}}} TECHNICAL question papers TO MY EMAIL ID dinesh100701@gmail.com

2238


What is the tipical Online UPS input voltage for 20 KVA load ( 3 Phase or 1 Phase )? Why ? Explain it...?

2691


I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1798


what is difference between earthingpits,earthing grid & earthing mess?

2557


Is any generator is developed which is operated with out diesal or other expensive source?

2143


In EHV transmission line a neutral grounding reactor is often placed at neutral point of shunt reactors. What is the recommended protection for this neutral grounding reactor? Should I use a fast closing switch to bypass neutral grounding reactor when this protection operates?

3299


how many stairs have you climbed while you were coming

2226


What is the temperature PROFILE OF A FLUID W. R. T. Distance from a sphere to which it is IN CONTACT which is at constant temp.?

2111


can i use the six sigma method which is used in management area, in state estimation of power systems?