Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between void volume and delay volume
in HPLC?

Answer Posted / priyanka nayani

Delay volume is the volume between GPV & Detector.
Dead volume is the width of pipe that is the connection between column out let and detector(0.1mm or 0.01mm) based on the size which we have introduced the void volume changes.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

before starting analytical method valodation what you checking? and how giving preference to start validation?

779


While performing TOC sst analysis Zero shift disabled & sample analysis zero shift enabled why?

2835


4. Describe the operation of the Craig apparatus. Chapter.3 Equilibrium Processes in Separations

2697


We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

1885


why salisylic acid not using now days for disdolution calibration?

752


if peak get problamatic then what require to do?

781


[3/28, 20:52] Manoj P Venkatpurwar: how many impurities require to inject in assay specificity that how we can find out? and in Rs also how?

780


why cone formation during dissolution?

756


In rs method development when we are going area normalization method to dilute standard method?

1505


How can we calculate offset value pH measurment

1486


in sampling of raw material which side is pasted sampled labels

1823


in monograph 7 imp are there but in vendor showing 5 imp do not req to include 2 imp for that what will be justification?

709


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1849


What is a difference between potency and purity?

1190


how to selecet an exact coloumn for an new molecule development by hplc how to select exact salt as buffer for new molecule development by hplc what is the the process to select the mode of saparation of compoundes by hplc what is the use of ph of buffer what is use of buffer,ph,organic phase,ans methods how the molecules get saparated in coloumn,

2580