In a coal fired boiler furnace temp. is high but super
heater out let temp. low what reason for this?
Answer Posted / y v subba rao
Final super heater inlet steam temperature is well below than flue gas temperature of that zone(400degrees). Steam travels trough super heater coils with higher velocity(may be 25m/sec) as per the boiler design to meet the steam requirement of turbine. Hence the pretension time of steam is very less in super heater zone. More over there is always a temperature difference across the tube thickness. Due to this reasons super heater out let steam temperature is always much below than flue gas temperature in that zone. However the boiler itself will be designed in such a way.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job
what's the moog valve
our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?
why do you consider yourself a suitable candidate for this position
procedure of how to generate power in solar plant.
why airtel use + 24 volts and other operators use -48 volt
Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.
im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
what is restricted earth fault explain in details
can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525
How do you consider that you can improve and what assistance do you need to achieve this
how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?
Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.