why we are performing residue on ignition?

Answer Posted / swapna

Residue on ignition is useful to identification of inorganic substances present in the sample.while adding the sulfuric acid metals reacts with sulfuric acid to form their sulphates
.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Difference between hlaf and rlaf

1647


What is the calibration of uv process and preparation

1496


for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol

5293


What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?

306


inhouse product is in capsule form in combination and RLD is in tablet form then can we proceed for multimedia CDP? in inhouse capsule product disso is paddle with sinker in release media is there then RLD product in tablet form then with same as paddle with sinker we can proceed n.a.?

289






Which parameters require to do in tech transfer?

270


How we performed the force degradation for drug substance, is any specific guideline is available for each parameter(Acidic, basic, oxidation,heat)? what conditions you mentained for above parameters.

1788


how to set sample and standard concentration in RS method?

356


Please tell me about the pH of Polycaboxylic ether is it in the 5-6 range ever or more than 6

2104


EXPLAIN THE CALCULATION PART OF AN KF TITRATOR CALIBRATION WITH SUITABLE EXAMPLE

2130


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

2973


please explian me about area normalisation method,diluted standard method,impurity vs impurity and which one has to be selected in method development

1098


in sampling of raw material which side is pasted sampled labels

1247


How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?

1301


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1109