Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we are taking 89ml concentrated HCL for preparing 1N HCL

Answer Posted / jyoti temkar

Actual strength of commercial HCl is 36%.
Molecular wt of HCl is 36.5
Density is 1.18 g/ml
So wt of HCl for 1 M is 36.5/(36/100) for 1000 ml
As volume = mass/ density,
Volume of HCl for 1M Strength in 1000 ml will be
36.5*100/(36*1.18)
=89 ml

Is This Answer Correct ?    19 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in which situation ion pair agent require to use?

724


about method developement in hplc

1708


if you given one product then which tests you will perform?

698


if instrument calibration fails then what require to do?

972


If vendor having more imp than monograph then how to proceed? and how to set spec?

917


What is dose dumping? why require to do?

936


From where require to take the RLD sample?

747


how can give the expiry period and restadardisation of volumetric solution

2582


in which situation require to change rs specification?

741


How to set specification of assay, fisdolution and related substances?

863


how to select short coloum and long coloumn for new molecule

2432


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4050


What are the primary considerations in extractables and Leachables ?

2267


In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )

3472


why we are using benzene, anyline in acetic anhdride assay titration method?

2106