how to reduce the co level in your 1000kva dg set side?

Answer Posted / satya dev

There are so many factors to emmiring the CO of generator set eg. poor filterarion of fuel,rocker leaver arm are not adjuested properly that is why fuel not consuming properly. fuel quality may not be good.

So you need to set all the parameters and operate the genetaror atleast 80% load to reduce the CO level.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

earth also having a gravitational force (magnetic field of north and south)but it attracts any object compare to this theartifical magnetic cant perform same as earth why?

1385


What is the function of interposing current transformer?

596


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1491


which pump used in WTP explain the function of VFD how to dtermine capacitorbank of capacity one plant

1468


Can a generator runs after getting 1st stator earth fault.

949






how to calculate the breaking capacity of different breakers.

1684


1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?

1369


How many types of instrument cables are there?

620


how to find out cable size if load is 2800 watts, 230 volts AC supply and load distance is 1800 meters

1083


How many types of colling system it trformers?

718


define displacement & magnitude ?

1385


ii) A shunt motor supplied at 230V, runs at 900 rpm when the current is 30A. The resistance of the armature is 0.4 ohms. Calculate the resistance required in series with the armature to reduce the speed to 600 rpm, assuming that the armature current is then 20A. [12]

1849


A logic circuit that provides a HIGH output if one input or the other input, but not both, is HIGH, is a(n)?

669


2. What are the parameters of EHT sub-station?

1834


What are the advantages of autotransformer?

754