Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

we have 3*1 MW generator one NGR is common for all it will
be selected during paralle our problem is two generator ca
be paralled but when slecting third one we need to close
NGR selection on third one other wise voltage not matching
why?

Answer Posted / k.prakashchandra

To establish relationship between I/C generator and the grid / bus bar/ other two gen through earth

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is mean by kneepoint voltage? when it will happen? ( my doubt is, if CT secondary is open means ct get saturation or blas? what are factors are required for calculations? plz give currect anws:

2017


What is the rate of WCT on the Electrical Contracts comprising of DG Sets and Civil Works in Delhi ?

2177


What is real time power factor control panel(RTPFC)?

4295


explain different losses in a transformer.

1092


How to calculate size of HT breaker with the help of Amp (current)? Please provide answers with examples.

2318


why various test are performed on electrical panels & power cables before commissioning on site & what are these test???

1973


how a flip flop can be used as a latch?

1972


WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.

1897


I have 1500/1A CT If i connect this CT in 6.6KV bus bar means what will be the voltage present in CT?

1984


what is RFID? thire application;

2021


what is the voltage between earth to neutral in lift.

1802


How can we calculate strength of copper hich is supplying electric power to heater and in it hold the heater also and what r all types of forces which is acting on it...

1963


what is earth pit , how we can measured it, what earth rods reference

2585


I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)

1872


132/66kv sub-station procation ?

2244