on 22.03.2015 at 17:15hrs Y phase 66kV class Power Trf-2 Current transformer has flashed over and oil came out. The failed CT has been replaced on 24.03.2015 at 13:15hrs and the Trf has been charged in presence of RT Hassan after conducting the pre-commissioning tests. On the same day at 17:00hrs the commissioned CT has again flashed over and immediately the Trf has been isolated from power supply. It is confirmed the secondary is not opened and checked the earth integrity and is found ok. Here what would be the reason for the CT failure?
Answer Posted / k.prakashchandra
Lightning stroke or metering core open circuited due to operation of faulty rotary phase selector
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?
what is the problem when i want to close a circuit breaker by local position it closes well.but when i close it in remote position it trips
What is bridge rectifier and explain with details
Is there a possibility to use such a treshold voltage for the NMOS part of a CMOS circuit that during the switching it will start conducting only after the PMOS part will be already closed, by this eliminating the leakedge current? Please note, I'm not asking about the well bias in standby mode, but about the "antileakedge" measures during normal operation.
why occ characteristics curve in not tracing back when we are bringing back the rhoestat?
why dimmerstate always connected in star connection? what will happen if it connected in delta?
Difference between shunt, PMG and AREP excitation. Which is the most reliable between PMG and AREP.
What type of fittings and electrical accessories can be install in radiation area ?
how to control the speed to switched reluctance motor
why we have and use 3 phase not 2 or 4 or other in power system?
what is the difference betweem star connected motor & delta connected motor?
can anyone please help me to find the rupturing or breaking capacity in KA of circuit breaker (MCCB,VCB,ACB etc) of HT and LT side of a distribution transformer...please help with detailed step by step answer...thank you
How much should be the load percentage for 15kva Inverter and Iinut & I output load with Calculations
what are the different methods for the starting of a synchronous motor.
Dear all: Recently we got a question about Interface between PMS and SAP-PM.once we got a update message from PMS.we should set the deletional flag for functional location in SAP system.Is there any FM or BAPI to use?There are only functional location create and change provided by SAP. Best regards!