Answer Posted / ayaz
please re-read the question we don't know which type of control valve but when pneumatic control valve shall write in question then we wrote the answer
input is 4-20 ma
output pneumatic depending on control valve bench set for example 3-15 psi or 6-30 psi
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
sir, i preparing hpcl,ongc,barc,hal exams(instrumentation engg)pls send a placement papers
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
What is difference of fanuc alpha series 16i and 18i controller.also what is differnce betn TC and MC controller
how to commission furnace ( water heater)
WHAT IS THE DIFF. BETWEEN SKIN TEMPERATURE AND PASSES TEMPERATURE..?
how to convert MA in to measuring values..and how mwasuring values into MA ?..plz ansr.i have intervw
what is a good line as ic engineer as maintenance ,oc, project, calibration ,validation engineer?
give me the formula for analog to digital converter and also d to a converter
If a control valve is hunting means means if we are giving 50% to the cv, the cv will open at 51% then slowly slwoly it will reaches 49% , so what to do for solve this problem. The cv is double acting and mounted for anti surge operation, it having 4 nos. volume booster, one sov, one positioner, etc..?
how can use ram
What is stripper & spilitter ? Diffrence in this.?
Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .
We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.
you must show the examples application and give at least 4 types of transducer/sensors that can minimize the failure during the manufacturing of the resistors.
What is the function of solenoid valve in on/off & shutdown valve and why it is not used in control valve normally?