Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Difference between ups

Answer Posted / mayank

1. UPS, standing for Uninterruptable Power Supply, is an
electric circuit (device) which instantly backs up power
supply for a gadget.On the other hand, inverter is circuitry
which converts AC to DC and stores in the battery.
2. Inverter converts DC power (stored in its battery) to
fulfill respective requirements of the devices.UPS does the
similar task of power supply and is quite similar to
inverter’s working in order to supply power.
3. Inverter has a wider range of input power as compared to UPS.
4. UPS circuitry is far more sophisticated than that of
inverters.

Is This Answer Correct ?    7 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.

1386


Why are short circuit ratings always 16kA,25kA,36kA and 50kA.Who has fixed these?

4272


what shoud be strength and weakness to impress interviewer????????

2058


State the methods of improving power factor?

1142


Is there any abbrevation for STUB in Stub bus protection

1929


What is genrally the % Impedance of a Dg set? How can we calculate Earthing conductor size for a DG set?

4018


What are the specifications for conducting earth leakage test as per IEC standard?

2052


what heppend if we are connected u1-v1-w1 as a star point in the place of u2-v2-w2 in power genration

2217


what is ratio of copper wire size and current ?

1822


May I know how much values to be set for earth fault, over current and short circuit values at 11kv side? I have 11kv van 1250amps rating. Present it's taking load 80amps?

1490


can anyone please help me to find the rupturing or breaking capacity in KA of circuit breaker (MCCB,VCB,ACB etc) of HT and LT side of a distribution transformer...please help with detailed step by step answer...thank you

1994


Please define ohm’s law for a.c (alternating current)?

1070


Difference between rating factor of cable and derating factor of cable?

1634


THERMAL CAPACITANCE IS MEASURED IN..................................................

2136


Is a 300w induction motor used in a food processor as powerful as a 1000w DC motor.

2217