Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Endcapped Hplc column

Answer Posted / satish jannu

Endcapping:it is a chemical treatment with trimethyl silane
to romove excess silanol groups in hplc column to get more
polar stationary phase

Is This Answer Correct ?    1 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1900


Related substance method equivalency on control sample or spiked sample?

824


give clarity of linearity and range in method validation

2476


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1654


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4135


How to set analyticl specification for combination products?

799


Which is the highly polar and highly non polar column in HPLC?

2348


what is mean by ambient temperature?

983


in dissolution if one bowl got 70 percent 2nd bowl got 80 percent and 3rd bowl got 90 percent then how proceed?

809


Why do we use KMnO4 in the test of control of obsorbance ? and why do we take specific quantity i.e 57-63mg?

2893


why we are using hexane in calibration of number of drop per mL

1796


in which situation ion pair agent require to use?

801


please explian me about area normalisation method,diluted standard method,impurity vs impurity and which one has to be selected in method development

1691


in dissolution why pool sample needed? in which type of drug pool sample need?

3225


Why sodium hydroxide used for maintain pH of phosphate buffer

2486