Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the diffirence between deviation and change control?
at what situations we can raise the deviation and change
control

Answer Posted / santhosh matam

Deviation: Departure from the approved manufacturing
process/SOP/Systems shall be considered as a deviation
management system. This is an unexpected event occurring
which is out of control. The concept of Planned deviation
is wiped out long back. There is no planned deviation as
such. As planned deviation is a non compliance to the
approved process/SOP/Systems.

Change control System: Any change in the process/SOP/Systems
shall be changed from approved Change Control Procedure.
Change control procedure denotes permanent change and
temporary changes. After getting assessment from CFTs & QA,
change can be implemented by validating the procedures. If
there are any discrepancies identified at the
initial(Validation stage), immediately this can be revert
back to the original state by closing the change control and
stated as not approved. If found no discrepancy this
temporary change control shall be approved and converted
into a permanent change. Some change controls can be made
permanent when we know the

Is This Answer Correct ?    46 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why SLS used as dissolution medium

1189


What aspect of your communications skills have you improved the most in and how did you accomplish this improvement?

2448


what is the leak test procedure of filled bottles (liquid)

2265


why nitrogen charecter as a inert gas plz identified

1721


What is the basic requirement for preparing drug master file , like EDMF , USDMF ?

2831


How to do IR test of hydroscopic materials

2036


what is the mechanism of action of local anaesthetics?

2344


when i come in contact with any metal items or clothes of fur i find myself shock and when run my fingers on fur clothes or matters, i find sparks. Is there any vitiams deffecieny in my body. If so, what i have to do?

2314


Iam a B.PHARMA GRADUATE from DELHI UNIVERSITY and I am looking forward for DRUG INSPECTOR EXAM..kindly mail me any ques papaers reg the same...

2265


WHAT IS MEANING OF DEAIATION WITH EXAMPLE

2741


how to calculate potency of working standard by using mass balence method & this calculated potency is on as basis or on anhydrous/ dried basis

9061


What is difference between Warm and Lukewarm Water as per pharmacopia.

1564


while formulation of Gliclazide floating tablets why we are using direct cmpression technique why not wet granulation and what happend with that

2665


plz.mail me model papers of drug inspector of chhattisgarh..or MP.if Posible. Mail Id-recha_1428@rediffmail.com...mrs_1428@rediffmail.com,

2466


What is the role of buffers (ex: KH2PO4) in HPLC analysis,

1768